Main steam pipeline of 900MW thermal power generating unit
User: Shanghai Waigaoqiao Power Plant Application location: Main steam pipeline of 900MW thermal power generating unit Pipeline parameters: Diameter: Φ840mm × 48mm; Material: P91; Processing procedure: Cutting, single-sided beveling for one-time formation, fully cold cutting; Processing tools: Tri-Be3036 type ring cutting and beveling machine Processing range: 762mm (30") - 914.4mm (36") |