Details

The on-site disassembly and repair project of the bypass valve GGS-12V for the R14 high-pressure heater of Qinshan Nuclear Power Plant No.1 Unit

秦山核电一厂R14高加旁路阀GGS-12V在线解体修复工程:密封面蓝油检查.jpg

Sealing surface lubricating oil inspection

秦山核电一厂R14高加旁路阀GGS-12V在线解体修复工程:修复前阀门(DN500楔式闸阀)工况.jpg

Working condition of the valve before repair (DN500 wedge gate valve)

秦山核电一厂R14高加旁路阀GGS-12V在线解体修复工程:修复完成后工况.jpg

After the repair is completed, the operating conditions

秦山核电一厂R14高加旁路阀GGS-12V在线解体修复工程:自密封吹损缺陷.jpg

Self-sealing blow-off defect

秦山核电一厂R14主蒸汽隔离阀电磁阀密封面在线修复工程:密封面PT检测.jpg

Sealing surface PT inspection

秦山核电一厂R14主蒸汽隔离阀电磁阀密封面在线修复工程:密封面损伤缺陷.jpg

Sealed surface damage defect

秦山核电一厂R14主蒸汽隔离阀电磁阀密封面在线修复工程:密封面损伤缺陷2.jpg

Sealed surface damage defect